NORMAL RESISTANCE – SELECT YOUR LOAD CONNECTION:
PURE RESISTIVE LOAD
In this application, REVO S family up to 700A is normally used. Over this current we recommend the Multidrive family up to a current of 2700A. REVO M family is also appreciated for communication, voltage compensation and burst firing.
REVO PC is used to avoid Power Peak and Enegy Saving.
LOAD ON SECONDARY OF TRANSFORMER
Transformer have inrush current on start up. Special Tyristor Power Controller are required. REVO CL up to 700A is normally used for 1PH loads. Over this current we recommend the Multidrive family up to a current of 2700A. REVO E and Multidrive is used for three phase transformer.
CD_AppNotes_eng_Application Notes_-_Transformers.pdf
Reduce Power Peaks and Maximise Your Savings
Have You Considered How Peak Power Could be a Problem to Your Business?
REVO PC is Capable of Maintaining the Power Below your contractual Limits, Allowing You to Choose the Right Consumption Most Convenient to Your Business.
Mishandling the Use of Power Results in Higher cost and Expensive Penalties for Exceeding the Contractual limits. Today, Thanks to REVO PC Technology and our Thyristor Units, all This is Under Control. Key Benefits Include:
- Synchronize the Demand for Primary Power.
- Eliminate the Peak Instantaneous Power
- Bringing the Power Factor Close to 1.
- Minimizes Energy Cost.
- Fieldbus Communication
- Heater Break and Thyristor Short Circuit Alarms.
- A Good Investment Can Save Money.
Pure Resistive Element | 1PH Load
Click on Product Name or Immage to see full description of the product For application with several units when the total power is high it is suggested PC REVO unit PC. In case o sincronization needed use it with REVO s 1PH series.
Pure Resistive Elements on the Secondary of 1PH Transformer
Select the SCR ( thyristor ) controller for Pure Resistive Elements on the Secondary of 1PH Transformer.
Transformer have inrush current on start up for this reason special SCR Power Controller are required. For 1ph load REVO CL up to 700A is normally used. Over this current we recommend the Multidrive family up to a current of 2700A. Multidrive and REVO E is used for three phase transformer.
Pure Resistive Element | Delta | Star Without Neutral
Select your Thyristor ( SCR ) Power Controller for pure resistive element | delta | star w/out neutral
Pure Resistive Element | Star With Neutral | Open Delta
Select your SCR ( Thyristor ) Power Controller for Pure Resistive Element | Star With Neutral | Open Delta
Pure Resistive Load on Secondary of 3ph Transformer
Thyristor Power Controller designed to Drive Three Phase Transformers Coupled on Secondary With Pure Resistive Loads.