- Home
- Thyristor Power Controller
- Single Phase (1PH) Load
Single Phase (1PH) Load
REVO S 1PH Single phase static relay
REVO S 1PH
- From 30 up to 800A
- Voltage Range 480V, 600V and 690V
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std, 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Zero Crossing, Burst Firing available with analogue input only
REVO SSR Long Life Solid State Relay
REVO SSR Long Life Solid State Relay
- Range: 0:62; 0:74; 0:90
- Max. voltage 480V or 600Vac as option
- Load type: Resistance
- Input: SSR
- Firing mode: Zero Crossing
REVO SSR ANALOG | 0:10V & 4:20mA Input SSR
REVO SSR ANALOG | 0:10V & 4:20mA Input SSR
- Rating 0:62; 0:74 and 0:90
- Max. voltage 480V or 600Vac as option
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: 0:10V, 4:20mA and Heather Break alarm are options
- Firing mode: Burst Firing
REVO Sx | Multiple Low Power Solid State Relay
REVO Sx - Multiple Low Power Solid State Relay
- From 3.5 to 7A
- Max. voltage 240V or 480V AC as option
- From 50 to 90A
- Max. voltage 480V or 600V AC
- Load type: Resistance, IR Lamp long and medium waveform
- Inputs: SSR Std
- Firing mode: Zero Crossing
REVO C 1PH – Revo Connect Universal SCR Power Controller Single Phase
REVO C 1PH
- Phases: 1
- Current Range from 30 to 2100A.
- Voltage Range 480V, 600V and 690V.
- Inputs: 4:20mA, 0:10V, SSR and ModBus as std and different Field Bus Listed in the Product Coding
- Firing mode: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering, Phase Angle with or without Soft Start
- Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
- USB: port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- 100 kA: Short Circuit Current Rating (SCCR) up to 600V
- Approvals CE+EMC; EAC; cUL from 30A to 700A, UL from 800A to 2100A
Revo PN – Suitable to control Electric Heaters and IR Lamps in Industrial Heating Systems
REVO PN
- Modules of 12 or 24 zones already divided into three phases or one phase from 4 to 24 zones
- Logic input SSR 7÷30Vdc 9mA Max (ON ≥7Vdc OFF <6Vdc)
- L1 - L2 - L3 Power Input 370 - 480V
- Nominal current in continuous service Max 25A for each load
- Max peak current (10ms) 700A
- Nominal Voltage range Ue 24 - 600V
- Isolation Voltage Ui 2500Vac
REVO PB – Three one phase SCR power controller with power optimization algorithm
REVO PB
REVO TH – Compact power controller with modular multi-zone SCR
REVO TH
REVO RT – 3-zone PID power controller up to 90A
REVO RT
REVEX 1PH – The Power Controller On Demand
REVEX 1PH
Technical Specification
- Load type: Normal Resistance, Infrared Short, Medium and Long, Transformer Primary, Cold resistance and SiC elements
- Inputs: 4:20mA, 0:10V, SSR and ModBus as std.
- Firing mode: Half Cycle, Single Cycle, Burst Firing, Delayed Triggering, Phase Angle with or without Soft Start
- Control Mode: Voltage, Current and Power or V2 and I2 with additional Transfer to VxI
- Communication: RS485 port. RTU Modbus® Protocol
- USB: Port integrated for configuration in safety mode (No Load and Auxiliary Voltage needed) Unit Powered Through USB
- Approvals: Comply with CE+EMC / EAC
- Dual Current Limit: For peak and RMS value
CD3000S 1PH – From 10A to 90A
CD3000S 1PH
Technical Specification
- Voltage power supply: 24V min, 480V Max, 600V on request
- Input Signal: SSR , Analog 4÷20mA and 0÷10V is available as an option on units from 15A÷90A included
- Firing: Zero crossing ZC / Burst Firing
- Fan Voltage: Supply 230V ± 15% (110V is available as an option)
- Heater Break Alarm: Discrimination better than 20%. * Circuit microprocessor based to diagnose partial or total load failure and short circuit on Thyristor. * Latching alarm plus reset. * Relay output 1A at 230V. * Automatic calibration of one or more unit at the same time using a dedicated digital input or using for each unit the calibration button.
- Approvals: EMC; cULus available as an option on basic units
- Mounting: Din rail mounting up to 90A included, bulkhead over 110A, IP20 protection
- Operating Temperature: 0÷40° up to 90A included (for higher temperature see the derating curve)